Laboratory accreditation standards describe how a lab must operate: its people, methods, equipment, records and impartiality. They do not describe what is in your vial. For a peptide vendor, manufacturer or buyer, two questions matter: what a standard says about the lab, and what the certificate of analysis says about the sample. We are KMD Analytical, an independent third-party peptide testing lab in Chatsworth, California. We test mail-in vials, we do not sell peptides, and we have no stake in any result. This guide explains the standards and then shows what a certificate must contain for the result to be useful.

Summary

  • ISO/IEC 17025 is the international standard for testing and calibration laboratories. It covers the lab’s competence, not the product that was tested.
  • Accreditation is granted by an accreditation body for a defined scope of tests. A certificate or logo means little until you read what that scope lists.
  • A peptide certificate should report identity, chromatographic purity and net-peptide content as separate results, with every active in a blend on its own row.
  • Every KMD certificate is sealed with a SHA-256 hash and can be checked at kmdanalytical.com/verify.

Table of Contents

What a laboratory accreditation standard is

A standard is a written set of requirements. Accreditation is an outside body’s finding that a lab meets those requirements for specific work. The standard most testing labs are measured against is ISO/IEC 17025. It lets a lab show that it operates competently and produces valid results, which supports acceptance of its reports across borders. The current edition is from 2017 and replaced the 2005 edition. It added risk-based thinking and aligned with ISO 9001.

The standard combines two kinds of clauses. Management clauses cover how the lab organizes itself. Technical clauses cover impartiality, personnel competence, facilities and equipment, method selection, verification and validation, sampling, item handling, technical records, measurement uncertainty and statements of conformity.

Management and technical areas covered by ISO 17025

Medical laboratories that examine patient samples are assessed against a separate standard, ISO 15189. It does not apply to a lab that analyzes the contents of a vial.

In the United States, the accreditation bodies you will meet most often are A2LA and NIST’s NVLAP program. NVLAP’s handbook incorporates ISO/IEC 17025 requirements, and accreditation is formalized by a certificate and a scope listing the test methods or services covered. A2LA’s biological testing program follows ISO/IEC 17025:2017 as well. AOAC INTERNATIONAL publishes ALACC guidelines that interpret the standard section by section for chemical and microbiological labs in sectors such as dietary supplements and pharmaceuticals.

Accreditation versus certification

People often say “ISO certified” when they mean something else. The two words describe different things:

Term What it means Who assesses
Accreditation (ISO/IEC 17025) A lab’s competence for specific tests, judged against technical and management requirements An accreditation body
Management system certification A check of the management system only, which ASCB notes is substantively an ISO 9001 check and does not cover the technical clauses A certification body
Product certification A conclusion about a product, governed by ISO/IEC 17065 A product certification body

NIST makes the same point: NVLAP is not a certifier of test data or products. It verifies that a lab has an appropriate quality management system and can perform certain methods within its scope. The accreditation period is one year and is renewed by demonstrating continued compliance.

So “ISO certified” on a lab’s website does not tell you the lab was assessed for any particular test. The wording you want to see is accreditation, by a named body, with a scope you can read.

What accreditation does not guarantee

NIST states that accreditation does not imply any guarantee of laboratory performance or of test or calibration data. It is solely a finding of laboratory competence. The use of an accreditation name or symbol must not imply product certification.

Three consequences follow for anyone buying testing or reading a certificate:

  1. It concerns the lab, not the item. A report from an accredited lab is a statement about the sample the lab received. It is not an approval of the product the sample came from.
  2. A statement of conformity is a separate step. Saying a result “passes” requires a decision rule, which defines how measurement uncertainty is treated in pass/fail calls. ASCB’s overview says it must be agreed with the customer before the work is done.
  3. Accreditation is not a safety or efficacy statement. It says nothing about whether any compound is suitable for any use.

The same logic applies to any certificate of analysis, ours included. A KMD certificate reports analytical results on the submitted sample only. It is not an endorsement of a product and not a statement about safety.

Reading an accreditation scope

When a lab cites accreditation, the document that matters is the scope. A2LA’s general requirements describe the scope as the official listing of tests and technologies a lab is deemed competent to perform, identifying materials or products, parameters and methods. A2LA does not accredit to a manufacturer’s or client’s product specification.

A2LA’s FAQ adds that a scope does not always include every capability a lab has, and capabilities not listed on the scope are not covered by the accreditation. A lab may have requested a limited scope, or assessors may not have been able to affirm competence in every area sought.

For any lab, check the following on the accreditation body’s public directory:

  • The accreditation status is active and has not expired.
  • The scope names the exact method and parameter you are relying on, such as chromatographic purity by HPLC, rather than a neighboring technique.
  • The performing site matches the address that issued the report.
  • The certificate you were shown is the one the directory lists.

The same discipline applies to us. Our methods, matrices and limits are set out on our scope of services page, and our lab facts page lists methods, prices and address, so you can read exactly what a KMD certificate covers before you submit a vial.

What a peptide certificate must show

Whatever a lab’s credentials, the certificate is the document you will hand to a customer, a regulator or your own quality file. Three questions are distinct, and a good certificate answers each separately:

  • Identity. Is the main compound the one on the label? We establish identity by retention-time and UV-spectral match against a reference standard. Our guide on how peptide identity is confirmed walks through it.
  • Chromatographic purity (area %). Of the signal the method detected, what share belongs to the main peak? A figure such as 99% describes a share of detected signal under one method. It says nothing on its own about identity or quantity.
  • Net-peptide content (mg per vial). How much active peptide is in the vial, as opposed to water, salts and counter-ions? This is the figure that tells you whether the label claim holds. Our content specification is at least 90% of label claim, with no upper cap.

Imagine two vials that both show 99% purity. One holds 5 mg of peptide and the other holds 3 mg, because the second contains more salt and moisture. Purity alone cannot separate them. Content in mg per vial does.

For a worked example of how a certificate is laid out, see this guide to reading a certificate of analysis.

Blends

A vial with several actives cannot honestly carry one purity number. On a KMD certificate every active in a blend is reported on its own row, each with its own identity, purity and content. A blend never gets a single purity figure. For an example of a two-active vial, see our GHK-Cu and KPV blend testing page.

Why ICH Q2(R2) matters here

The ICH Q2(R2) guideline treats identity, impurity and assay as distinct analytical purposes. That is the reasoning behind reporting three results, not one. A certificate that offers only a purity percentage leaves the other two questions open.

How we test

We use reversed-phase HPLC with UV diode-array detection (RP-HPLC-UV) on an Agilent HPLC-DAD, with quantitation at 214 nm. Each result is measured against a reference standard. Every certificate reports identity, chromatographic purity (area %) and net-peptide content (mg per vial).

Our certificates are sealed with a SHA-256 hash, which is a cryptographic fingerprint of the document. Each carries a unique ID and a QR code, so anyone, including your customer, can confirm at kmdanalytical.com/verify that it is genuine and unaltered. Our post on looking up and verifying a peptide certificate shows the steps.

Endotoxin testing

If your certificate package also needs bacterial endotoxin data, we run USP <85> kinetic chromogenic LAL testing, with the result reported in EU/mL, at $150 per vial. It is not a sterility test. It measures endotoxin, and it does not show whether a vial is sterile.

A short checklist for buyers and vendors

Use this on any certificate you receive or issue:

  1. Does it name the analyte and carry a sample or lot ID?
  2. Does it state the method and the units of each result?
  3. Are identity, purity and content reported as three separate results?
  4. If the vial is a blend, does each active have its own row?
  5. Does it state the specification the content was compared with?
  6. Can you confirm the document with the issuing lab, for example through a unique ID or QR code?
  7. If accreditation is cited, can you find the named body, the active status and the exact method in the scope?
  8. Is the report clear that it describes the submitted sample only, not the product as a whole?

Pricing and turnaround for third-party testing

Our published per-vial pricing for identity, purity and assay by RP-HPLC-UV:

Vials per order Price per vial
1 to 4 $150
5 to 9 $125
10 or more $100

Blends cost 50% more per additional active beyond the first. Solution pH is $20 and bacteriostatic water testing is $75. Typical turnaround is 5 to 7 business days, with 7 as the maximum.

Rush service returns results the next business day for a 100% surcharge. It is limited to up to 4 vials, and vials must be received by 12:00 PT. Same-day service is by arrangement only, at a 150% surcharge, with vials received by 10:00 AM PT. It is not available on the order form.

For group-testing organizers, the volume tiers matter: a group that pools ten vials into one order pays $100 per vial, not $150. We do not test controlled substances, HGH/somatropin, testosterone or steroids, or SARMs.

Our view

Accreditation and certificates answer different questions, and buyers get into trouble when they treat one as the other. A standard tells you how a lab is run. A certificate tells you what the lab found in one vial.

Because we do not sell peptides, a result can only be what the chromatogram shows. That independence is the reason a vendor can hand our certificate to a customer and have it carry weight.

We build each certificate so it can be checked without trusting us. The method is stated: RP-HPLC-UV, quantitation at 214 nm. Identity is a retention-time and spectral match against a reference standard. Purity and content are separate numbers. Every active in a blend gets its own row. The seal and QR code let your customer confirm the document in seconds.

We also keep the claims modest. A certificate describes the submitted sample. It does not endorse a product and it makes no statement about safety.

kevin

Put a verifiable certificate behind your product

If you are a vendor, manufacturer or researcher who needs third-party data you can hand to someone else, we test mail-in vials and return a sealed certificate with identity, chromatographic purity and net-peptide content. See our peptide testing service and pricing, or read about testing for vendors and brands.

Kmdanalytical

Ongoing testing programs and method development are also available. You can start from kmdanalytical.com.

FAQ

Is ISO/IEC 17025 an accreditation or a certification?

It is an accreditation standard. An accreditation body assesses a lab’s competence against it for a defined scope. A certificate from a management-system certification body covers only the management system, not the technical clauses, according to ASCB.

Does accreditation prove a product is safe or effective?

No. NIST describes accreditation as a finding of laboratory competence, not a guarantee of performance or data and not a product certification. A certificate of analysis likewise reports on the submitted sample only.

How do I check a lab’s accreditation scope?

Look up the lab in the accreditation body’s public directory. Confirm that the status is active, that the scope lists the exact method and parameter, and that the performing site matches the report. A2LA notes that unlisted capabilities are not covered by its accreditation.

Why does a peptide certificate need three separate results?

Identity, purity and content answer different questions. Purity is a share of detected signal, content is the amount in the vial, and identity confirms the compound. We report all three on every certificate, and each active in a blend gets its own row.

Is endotoxin testing the same as sterility testing?

No. Our USP <85> kinetic chromogenic LAL test reports endotoxin in EU/mL at $150 per vial. It is not a sterility test.

Sources

Recommended

KMD Analytical reports analytical results on submitted samples only. Nothing here is medical advice or a statement that any product is safe or suitable for use.